Displays the CPU utilization on the specified bridge port extenders BPE(s).
vpex | Specifies VPEX. |
bpe | Specifies BPE. |
slot | Specifies a specific BPE by slot number. |
slot_num | Specifies a specific BPE by slot number. |
cpu-utilization | Specifies showing CPU information. |
N/A.
The following example shows CPU information for all BPEs attached to the control bridge (CB):
# show vpex bpe cpu-utilization Slot: 100 Cascade Port: 1:44 MAC: d8:84:66:88:98:06 CPU Utilization: 5 seconds: 28 % 1 minute: 16 % 5 minutes: 16 % Slot: 101 Cascade Port: 1:45 MAC: d8:84:66:88:98:07 CPU Utilization: 5 seconds: 29 % 1 minute: 17 % 5 minutes: 18 %
This command was first available in ExtremeXOS 22.5.
This command is available on ExtremeSwitching 5420 and 5520 series switches, and Extreme 7520-48Y switches.